您現在的位置:首頁 > 產品展示 > 介損測試儀 > 變頻抗干擾介質損耗測試儀 > KTJSYBP變頻介質損耗測試儀

變頻介質損耗測試儀

簡要描述:變頻抗干擾介質損耗測試儀是發電廠、變電站等現場全自動測量各種高壓電力設備介損正切值及電容量的高精度儀器。
儀(yi)器(qi)為體化(hua)結(jie)構,內置介損(sun)電橋、變頻(pin)電源(yuan)、試驗(yan)變壓器(qi)和標準電容器(qi)等。采用變頻(pin)抗干擾(rao)和傅(fu)立葉變換(huan)數字(zi)濾(lv)波技術,全自動智能化(hua)測量(liang),強干擾(rao)下測量(liang)數據非常穩定。測量(liang)結(jie)果由大屏幕液晶顯示(shi),自帶(dai)微(wei)型(xing)打印機(ji)可打印輸(shu)出。

  • 產品型號:KTJSYBP
  • 廠商性質:生產廠家
  • 更新時(shi)間:2023-09-18
  • 訪  問  量:1316

 

 

 


 

變頻(pin)抗干擾介質損耗測試儀(yi)是發(fa)電廠(chang)、變電站等現場全自動測量(liang)各種高壓(ya)電力設(she)備介損正(zheng)切(qie)值及電容量(liang)的高精度(du)儀器。
儀器(qi)為體化(hua)(hua)結構,內置介(jie)損電橋、變(bian)(bian)頻(pin)電源、試驗變(bian)(bian)壓器(qi)和標準電容器(qi)等。采用變(bian)(bian)頻(pin)抗干擾(rao)和傅立葉變(bian)(bian)換數字(zi)濾波(bo)技術,全自(zi)動智能化(hua)(hua)測(ce)量,強干擾(rao)下(xia)測(ce)量數據(ju)非常穩定。測(ce)量結果(guo)由大屏幕液(ye)晶顯(xian)示,自(zi)帶微型打印(yin)(yin)機可打印(yin)(yin)輸出。
 
產品特點
KTJSYBP變頻抗干擾介質損耗測試儀(yi)采用變頻(pin)抗(kang)干擾(rao)技術,在200%干擾下仍能準確測量,測試數據穩定(ding),適合在現場(chang)做抗干擾介損試驗。
高精度測(ce)量
變頻抗(kang)干擾介質損耗(hao)測試儀(yi)采用(yong)數(shu)字波形分析和電橋自(zi)校(xiao)準等(deng)技(ji)術,配(pei)合(he)高精(jing)度三端標準電容(rong)器,實現高精(jing)度介損測量。
變(bian)頻抗干(gan)擾介(jie)質損(sun)耗測試儀所有(you)量程輸入電阻低(di)于(yu),消除了測量電纜(lan)附加電容的(de)影響。
多級安(an)全保(bao)護,確保(bao)人身(shen)和(he)設備安(an)全
高壓保(bao)護:試品短路、擊穿或(huo)高(gao)壓(ya)電流波動(dong),能(neng)以短路方式高(gao)速切斷輸出。
低壓(ya)保護(hu):誤接380V、電(dian)源波動(dong)或突然(ran)斷電(dian),啟動(dong)保護(hu),不會引(yin)起過電(dian)壓。
接地保護:儀器接(jie)地不(bu)良使外殼(ke)帶危險電(dian)壓(ya)時,啟動接(jie)地保護。
CVT高壓(ya)電(dian)(dian)(dian)(dian)壓(ya)和電(dian)(dian)(dian)(dian)流、低壓(ya)電(dian)(dian)(dian)(dian)壓(ya)和電(dian)(dian)(dian)(dian)流四個保護限,不會損壞設備;誤選菜單不會輸出激(ji)磁電(dian)(dian)(dian)(dian)壓(ya)。CVT測量時無10kV高(gao)壓輸出(chu)。
防誤操作(zuo):兩級(ji)電(dian)源開關(guan);電(dian)壓(ya)、電(dian)流實時監(jian)示(shi);多次按鍵確(que)認;接(jie)線(xian)端(duan)子高/低壓分明;緩速升壓,可迅(xun)速降壓,聲光報警。
容升測量(liang)大容(rong)量(liang)試品時會出現電壓抬高的容(rong)升效應,儀器能自動跟蹤輸出電(dian)壓,保持(chi)試驗電(dian)壓恒定。
抗震性(xing)能(neng):儀器采用*抗震(zhen)設計,可耐受強(qiang)烈(lie)長(chang)途(tu)運輸震(zhen)動、顛簸(bo)而不會損壞。
高壓電纜:為耐高(gao)壓絕緣導(dao)線,可拖地使(shi)用。
功能強大,產(chan)品系列化
本起有兩種型號: E和(he)F型。
1具有正/反接(jie)線,內/外(wai)標準電容(rong),內(nei)/外高(gao)壓多(duo)種工作模式,體化結構(gou),可做各(ge)種常(chang)規介(jie)損試驗,不(bu)需外接任何輔(fu)助設備。
2)液晶顯示,菜單操作,測試數據豐富,自(zi)動分(fen)辨電(dian)容(rong)、電(dian)感、電(dian)阻型試品,自(zi)帶微型打印機可打印輸(shu)出。
3)具有(you)外(wai)接(jie)標準電(dian)容(rong)器接(jie)口,可(ke)(ke)外(wai)接(jie)油杯做精密絕(jue)緣油介(jie)損試(shi)驗(yan),可(ke)(ke)外(wai)接(jie)固(gu)體材料測(ce)量電(dian)極做精密絕(jue)緣材料介(jie)損試(shi)驗(yan),也(ye)可(ke)(ke)外(wai)接(jie)高壓(ya)(ya)標準電(dian)容(rong)器做高電(dian)壓(ya)(ya)介(jie)損試(shi)驗(yan)。
4)自動識別(bie)50Hz / 60Hz系(xi)統電(dian)源,并(bing)支持發電(dian)機供電(dian),即(ji)使頻率波動大(da),也可正(zheng)常測量(liang)。
5)內置(zhi)串聯(lian)和(he)并聯(lian)兩種(zhong)介損測(ce)量模型,方便(bian)儀器檢定。
6)可存儲255組測量數(shu)據。
7CVT自激法(fa)測量時,C1/C2可次接(jie)線同時測出(chu),自動補償母線接(jie)地(di)和(he)標準電容器的(de)分(fen)壓(ya)影響,無(wu)須(xu)換線和(he)外接(jie)任何配件。
8)中(zhong)文圖文菜(cai)單,大屏幕背光LCD顯示更清(qing)晰,電(dian)流電(dian)壓實時(shi)監視。
9)優(you)化的電路設計,使正/反接線的準確度和穩定(ding)性致。
10)自動識(shi)別外接高(gao)壓試驗電源(yuan)頻率40Hz70Hz,支持工頻電源、變(bian)頻電源和串(chuan)聯(lian)諧振電源做(zuo)大容量高(gao)電壓(ya)介損試驗。
11)具有反接線(xian)低壓(ya)屏蔽功能(neng),在220kVCVT母線接地情況下(xia),對C11可進(jin)行不拆線(xian)10kV反(fan)接(jie)線介損測量。
12)帶(dai)計算機接口(kou)。通過該接口(kou),實(shi)現測(ce)量、數據(ju)處(chu)理和(he)報表輸出(chu),也可(ke)實(shi)現儀器內部測(ce)量軟件升級。可(ke)集成到(dao)綜(zong)合高壓(ya)試驗車上。
F型(xing):除具備E型全部(bu)功(gong)能外,
(1)配置熱敏打印機,使打印更加快捷、無噪音和清晰。
(2)增加回路接觸不良放電提示功能,以方便判別接線是否可靠。
(3)增強反接線低壓屏蔽功能,可次接線同時測出兩個電容的電容量和介損值。
(4)增加CVT變比功能,可測量CVT變比和(he)相位誤差。
供貨范圍
1)儀器(qi)主機            ;              2)使用說明(ming)書(shu)和產品合(he)格證
3)測試(shi)電(dian)纜線     ;             4)電源線
5)備用色帶、打印紙和保險管(guan)    6)其它(ta)詳見(jian)《裝箱(xiang)單》
1主要功能
準(zhun)確(que)度:           Cx:      ±(讀數×1%+1pF
tgδ:     ±(讀數×1%+0.00040
抗干(gan)擾指標:變頻抗干擾,在200%干擾下仍能達到上述準確度
電容量范圍:      高壓:   3pF60000pF/10kV     60pF1μF/0.5kV
施(shi)高壓:   3pF1.5μF/10kV         60pF30μF/0.5kV
分辨率                 zui高0.001pF4位(wei)有效數字
tgδ范圍:   不限,分辨率0.001%,電容、電感、電阻(zu)三(san)種試品自(zi)動(dong)識別(bie)。
試驗電流范圍10μA
內(nei)施高壓:   設定電壓范圍(wei):0.510kV
zui大輸出(chu)電流:200mA
升降(jiang)壓方式:     連(lian)續平滑調(diao)節
電(dian)壓精度:   ±(1.5%×讀數+10V)
電壓(ya)分(fen)辨率:     1V
試驗頻率:   4550556065Hz單頻
45/55Hz55/65Hz47.5/52.5Hz自動雙變(bian)頻
頻率精度:   ±0.01Hz
外(wai)施(shi)高壓:   正接線時zui大試驗電流1A,工頻(pin)或變頻(pin)40-70Hz
反接線時(shi)zui大(da)試驗(yan)電流(liu)10kV/1A,工頻或(huo)變(bian)頻40-70Hz
CVT自(zi)激法低壓輸出:輸出電壓350V,輸(shu)出電(dian)流330A
測量(liang)時(shi)間:   40s,與(yu)測量方式(shi)有關
輸入電源:   180V270VAC50Hz/60Hz±1%,市電或發電機(ji)供電
計算機接口:      標準RS232接(jie)口
打(da)印機:           煒煌A7熱敏微型打印機(ji)
環境溫度:    -10℃~50℃
 
2面板(ban)介紹:
1高壓(ya)輸出插座(zuo)(0.5~10kV,zui大200mA)
安裝位置:箱體(ti)前側面(mian),外設保護門(men)。
    能:內高壓輸出;檢測反接線試品電流;內部標準電容器的高壓端。
接線(xian)(xian)(xian)方法(fa):插座1腳接高(gao)(gao)(gao)壓(ya)(ya)線(xian)(xian)(xian)芯(xin)線(xian)(xian)(xian)(紅(hong)夾子(zi)(zi)),2、3腳接高(gao)(gao)(gao)壓(ya)(ya)線(xian)(xian)(xian)屏(ping)蔽(黑(hei)夾子(zi)(zi))。正接線(xian)(xian)(xian)時(shi),高(gao)(gao)(gao)壓(ya)(ya)線(xian)(xian)(xian)芯(xin)線(xian)(xian)(xian)(紅(hong)夾子(zi)(zi))和屏(ping)蔽(黑(hei)夾子(zi)(zi))都可以用作加(jia)壓(ya)(ya)線(xian)(xian)(xian);反接線(xian)(xian)(xian)時(shi)只能用芯(xin)線(xian)(xian)(xian)對試品(pin)高(gao)(gao)(gao)壓(ya)(ya)端加(jia)壓(ya)(ya)。如果試品(pin)高(gao)(gao)(gao)壓(ya)(ya)端有屏(ping)蔽極(如高(gao)(gao)(gao)壓(ya)(ya)端的屏(ping)蔽環)可接高(gao)(gao)(gao)壓(ya)(ya)屏(ping)蔽,無屏(ping)蔽時(shi)高(gao)(gao)(gao)壓(ya)(ya)屏(ping)蔽懸空(kong)。
注意事項:
(1)儀器測量電(dian)(dian)纜(lan)通(tong)用(yong),建議用(yong)高壓線連接此(ci)插座。高壓插座和(he)高壓線有危險電(dian)(dian)壓,禁止碰觸高壓插座、電(dian)(dian)纜(lan)、夾(jia)子和(he)試品帶電(dian)(dian)部位!確認斷電(dian)(dian)后接線,測量時務必遠離!
(2)用標準(zhun)介(jie)損器(qi)(或標準(zhun)電容器(qi))檢定反(fan)接(jie)(jie)線(xian)精度時,應使(shi)用全屏蔽插頭連接(jie)(jie)試品,否則暴露的芯(xin)線(xian)會(hui)引起誤差(cha)。
(3)應(ying)保(bao)證高壓線(xian)與試品高壓端0電(dian)阻連接,否(fou)則可能引起(qi)誤差或數據波動(dong),也可能引起(qi)儀器(qi)保(bao)護。
(4)強干擾下(xia)拆除接線時(shi),應在保持(chi)電纜接地狀(zhuang)態(tai)下(xia)斷開連接,以防感(gan)應電擊。
2.2試(shi)品輸入Cx插座(10μA~1A)
    能:正接線時輸入試品電流。
接(jie)線(xian)方法(fa):插座1腳(jiao)接(jie)測量(liang)線(xian)芯(xin)線(xian)(紅夾(jia)子(zi)),2、3腳(jiao)接(jie)測量(liang)線(xian)屏(ping)(ping)蔽(bi)(bi)(黑夾(jia)子(zi))。正(zheng)接(jie)線(xian)時(shi)芯(xin)線(xian)(紅夾(jia)子(zi))接(jie)試品(pin)低壓(ya)信號端(duan)(duan),如果(guo)試品(pin)低壓(ya)端(duan)(duan)有(you)屏(ping)(ping)蔽(bi)(bi)極(ji)(如低壓(ya)端(duan)(duan)的(de)屏(ping)(ping)蔽(bi)(bi)環(huan))可接(jie)屏(ping)(ping)蔽(bi)(bi),試品(pin)無屏(ping)(ping)蔽(bi)(bi)時(shi)屏(ping)(ping)蔽(bi)(bi)懸空。
注意事項:
(1)測量中嚴(yan)禁拔下(xia)插頭(tou),防止試品電流(liu)經人體入地!
(2)用標準(zhun)介損器(或標準(zhun)電容器)檢測儀器正接線精度時(shi),應(ying)使用全(quan)屏蔽插頭連接試品,否則暴露的芯線會引起誤差。
(3)應保證(zheng)引線與試(shi)品低壓端0電阻連(lian)接,否則可(ke)能(neng)引起(qi)誤差或數(shu)據波(bo)動,也可(ke)能(neng)引起(qi)儀(yi)器(qi)保護。
(4)強干擾下拆除接(jie)線時,應(ying)在保持電纜(lan)接(jie)地狀(zhuang)態下斷開連接(jie),以防(fang)感應(ying)電擊。
2.3標準電(dian)容輸入Cn插座(10μA~1A)
    能:輸入外接標準電容器電流。
接線(xian)方法(fa):與(yu)Cx插座類似,其區別(bie)在于:
 
(1)使用外(wai)部(bu)標準電(dian)(dian)容器(qi)時,應使用全屏蔽插(cha)頭連(lian)接(jie)。此方式(shi)常用于外(wai)接(jie)高電(dian)(dian)壓等級標準電(dian)(dian)容器(qi),實現高電(dian)(dian)壓介損(sun)測量(liang)。
(2)菜單選擇“外Cn”方(fang)式。
(3)將外接標準電(dian)容器(qi)的C和tgδ置入儀器(qi),實現Cx電(dian)容介損的值(zhi)測量。
從原理上講,任(ren)何容(rong)量和介損的電容(rong)器(qi),將參數置入儀器(qi)都可做標(biao)(biao)準電容(rong)器(qi)。不同的是標(biao)(biao)準電容(rong)器(qi)能提供更(geng)好的長(chang)期穩定性和精(jing)度。
(4)不管正接線(xian)(xian)還是反(fan)接線(xian)(xian)測(ce)量,標準電(dian)容器(qi)接線(xian)(xian)方式始(shi)終(zhong)為正接線(xian)(xian)。
2.4 CVT自激法(fa)低壓輸出(chu)插座(zuo)(3~50V,3~30A)
    能:由該插座和接地接線柱輸出CVT測量的低壓變頻激勵電源。
注意事項:
(1)因低壓輸出電流大(da),應采用儀器低阻(zu)線連接CVT二次(ci)繞組(zu),接觸(chu)不良會影響測(ce)量(liang)。
(2)視CVT容量(liang)從菜單選擇合(he)適的電壓(ya)電流保護(hu)限。
(3)啟(qi)動CVT測量(liang)時,輸出2~5V的試(shi)探電壓(ya),若外部(bu)接(jie)線有(you)錯會(hui)自動停機。若懷疑儀器故障,可測量(liang)有(you)無該試(shi)探電壓(ya)。
(4)選擇正/反(fan)接線時(shi),此輸出封(feng)閉。
2.5測(ce)量(liang)接(jie)地接(jie)線柱(zhu)
它同外(wai)殼和電源(yuan)插座地線連(lian)到起。
注(zhu)意事(shi)項:
(1)盡管儀器有接地保護,但無論何種測量,儀器都應可靠獨立接地
(2)保證0電阻接(jie)地(di)(di)。應仔細檢(jian)查接(jie)地(di)(di)導體(ti)(ti)不(bu)能(neng)(neng)有油漆或(huo)銹蝕,否則應將接(jie)地(di)(di)導體(ti)(ti)刮干(gan)凈。輕微接(jie)地(di)(di)不(bu)良(liang)(liang)可(ke)能(neng)(neng)引(yin)起誤差或(huo)數據波動,嚴重(zhong)接(jie)地(di)(di)不(bu)良(liang)(liang)可(ke)能(neng)(neng)引(yin)起危險!
2.6電源(yuan)輸(shu)入插座(180V~270V 50Hz/60Hz)
注(zhu)意(yi)事(shi)項:
(1)KTJSYBPE變頻抗干擾介質損耗測試儀(yi)有快速斷電保護(hu)功(gong)能,低(di)壓突然斷電時迅速以短路方式切斷高壓輸出。此功(gong)能要求儀(yi)器的(de)低(di)壓電源(yuan)(插(cha)座、刀(dao)閘等)應(ying)可靠(kao)連(lian)接,否則(ze)超(chao)過數(shu)ms的(de)斷電便會引(yin)起保護(hu)。
(2)輸入電壓(ya)大于270V(如(ru)誤接380V),儀器立即保(bao)護,切斷內部電源。保(bao)護后只有總電源開關(guan)燈亮(liang),但(dan)屏幕無顯示(shi)。此時可檢查電源,重新開機。
(3)如果電壓過低,儀(yi)器(qi)無法輸出設定(ding)高壓,可用調壓器(qi)調整。
(4)儀器可以自動適(shi)應(ying)50Hz/60Hz電源頻率。
(5)采用發(fa)電(dian)(dian)機供電(dian)(dian)時,頻率(lv)波動大,且使用發(fa)電(dian)(dian)機的(de)場合不存在干擾,可選擇“定頻”模式,以排除發(fa)電(dian)(dian)機供電(dian)(dian)頻率(lv)波動的(de)影響。
2.7保險管(guan)座
保險(xian)管座與低壓電(dian)源(yuan)插座合(he)為體(ti),保險(xian)管規格(ge) / 250V,尺寸φ5×20mm。
注意事項:應使用(yong)(yong)相同規(gui)格的保險絲(si)。若換用(yong)(yong)備用(yong)(yong)保險絲(si)后仍燒斷,可能儀(yi)器(qi)有(you)故障,可通知(zhi)廠家處理。
2.8總(zong)電源開關
打開總電源開關(guan),先顯示儀器名稱和編號(hao),數秒(miao)后自動進入(ru)測量菜單。關(guan)閉此(ci)(ci)開關(guan),也同時關(guan)閉內部高壓系(xi)統電源,緊急情況應立即關(guan)閉此(ci)(ci)開關(guan)。
2.9按鍵
(1)“移(yi)動光標,“和“修(xiu)改光(guang)標處內容,“確定”用于確認(ren)或停止。詳細(xi)功(gong)能見各型號儀器(qi)的“使用說明(ming)”。注意:確(que)定”是個鍵,不要當做兩個按鍵使用。
(2)測量過(guo)程中,按確定鍵即終止測(ce)量。
2.11液晶顯示器
顯(xian)示菜單(dan)、測量結(jie)果(guo)或出錯信(xin)息。應(ying)避免(mian)長時間陽光爆(bao)曬,避免(mian)重壓。
2.12打(da)印機
手動打(da)印(yin):顯示(shi)可打(da)印(yin)數據時,按“打(da)印(yin)”鍵打(da)印(yin)。。
自動打(da)(da)印(yin)(yin):菜單選擇自動打(da)(da)印(yin)(yin)后,測量結束即自動打(da)(da)印(yin)(yin)結果,之后可在(zai)遠處切(qie)斷(duan)儀器供電(dian),使操作更加安(an)全。
換(huan)紙(zhi)(zhi)和色(se)(se)(se)帶:打(da)印(yin)機(ji)為(wei)M150型(xing)微(wei)型(xing)打(da)印(yin)機(ji)。打(da)印(yin)紙(zhi)(zhi)寬44mm。換(huan)紙(zhi)(zhi)時(shi)要拉出打(da)印(yin)機(ji)整(zheng)體,將紙(zhi)(zhi)送(song)入進紙(zhi)(zhi)口并按走(zou)紙(zhi)(zhi)鍵。換(huan)色(se)(se)(se)帶時(shi)取下(xia)上蓋,色(se)(se)(se)帶平直安(an)裝(zhuang)。
    KTJSYBP變頻抗干擾介質損耗測試(shi)儀配置熱敏打(da)(da)印機,使用寬度44mm熱敏打(da)(da)印紙(zhi)。換紙(zhi)時要打(da)(da)開打(da)(da)印機的紙(zhi)倉蓋板,放入(ru)紙(zhi)卷并留少許部分在外面,然后關閉蓋板。
2.13通訊接口(kou)
    能:RS232接口,與PC機或筆記本電腦的串行通訊口連接。為保證通訊正常,雙方應設置相同的波特率和通訊地址。
通訊(xun)協(xie)議:儀(yi)(yi)器與PC機(ji)按規定協(xie)議通訊(xun),實(shi)時操作儀(yi)(yi)器,實(shi)現數(shu)據(ju)存儲傳送等功能。
3.使用(yong)說明
 
3.1對(dui)比度調節
液晶顯示屏的對比度已在出廠時校好,如果您感覺不夠清晰,可用如下(xia)方法(fa)調(diao)整:
按住或(huo)不動,再打開總(zong)電源開關,再按或(huo)調整(zheng)顯(xian)示對比度(du),調整(zheng)完畢按(an)確(que)定鍵退出。
3.2進入菜單
打開總電源開關(guan)后(hou),先顯(xian)示開機畫面:

抗干擾
精密介損儀

 
 
 
 
 
 
 
然后自動進入測量(liang)菜單。

正接           Cn
變頻           內(nei)Un
        10kV
啟(qi)動
 

 
 
 
 
 
 
 
3.3選擇接線方(fang)式
光標在正(zheng)接,按↑↓選擇“正接”、“反接”和“CVT”測量(liang)方式。
3.4選擇內(nei)、外標準電容
光標在,按↑↓選擇“內標準”“外標準”,表示使用內或外接標準電容。通常可用內部標準作正、反接線測量和CVT自激法測量,高電壓介損選用外標準方式,需要將外接電容參數置入儀器。光標在“外cn”,按住“啟停”鍵1s以上出現外標準電容值,按↑↓鍵(jian) 可(ke)以修(xiu)改此(ci)數值。修(xiu)改完畢按(an)住“啟(qi)停”鍵(jian)1s左(zuo)右,聽到蜂鳴器響聲,松開鍵(jian)盤即(ji)可(ke)保(bao)存。
3.5選(xuan)擇試驗頻率
3.5.1開機默(mo)認頻率
光標在 “變頻”,表示45/55Hz自動變頻。儀器自動用45Hz和55Hz各測量次,然后計算50Hz下無干擾時數據。開機自動默認為該方式,建議使用。
3.5.2選擇更多(duo)頻率
光標在“變頻”,按住“啟停”鍵1s以上切換到全頻率選擇,按↑↓鍵循環顯(xian)示(shi)“45Hz / 50Hz / 55Hz / 60Hz / 65Hz / 50±5Hz / 60±5Hz / 50±2.5Hz”:
“50Hz”:為工頻測量,此設置(zhi)不能抗干擾(rao),在試驗室內測量或校驗時選用(yong)。
“45/55/60/65Hz”:為單頻(pin)率測量,研究不同頻(pin)率下介損的變(bian)化時選用。
“50±5Hz”:為45/55Hz自動(dong)變頻,適合50Hz電(dian)網工頻干(gan)擾下測(ce)量。
“60±5Hz”:為55/65Hz自動變(bian)頻(pin),適合60Hz電網工(gong)頻(pin)干擾下測量。
“50±2.5”:為47.5/52.5Hz自動(dong)變頻,適(shi)合50Hz電網工頻干擾下測量。
按住(zhu)“啟停”鍵1s以上(shang)取消全頻率選擇。
3.6選擇試驗高壓
3.6.1正/反接線方式(shi)下(xia)選擇(ze)高壓
光標在10kV,按↑↓鍵循環顯示試驗高壓“0.5 /0.6 /0.8 /1 /1.5 /2 /2.5 /3 /3.5 /4 /4.5 /5 /5.5 /6 /6.5 /7 /7.5 /8 /8.5 /9 /9.5 /10kV”。應根據高壓試驗規程選擇試驗高壓。
啟動測量后,該處顯示測量高壓.下方顯示In=158uA    Ix=10mA
In=158uA 表示流過標(biao)準(zhun)電容(rong)的電流,單位為 uA 。
Ix=10mA 表示(shi)流過(guo)試品的電流,單(dan)位為 mA 。
如果In=000 uA ,表示內部高壓沒有輸出,或儀器有問題。請先查看屏幕是否選擇為內Un,內Cn
3.6.2 CVT自激法接線方式下選擇高壓
CVT自激法測量必須使用內部高壓電源,由機內提供激勵電壓,由“CVT1”和“CVT2”輸出。通常測量C1時低壓激勵電壓可達20V,測量C2時低壓激勵電流可達1。般可設高壓電壓1.5~2kV。
3.7自動(dong)打(da)印(yin)
光標在10KV,按“確認”鍵可顯示或取消屏幕左下角處打印機圖標      ,有此圖標表示測量結束自動打印。
 
3.8啟動測量
光標在啟動,按住“確認”鍵1s以上啟動測量。
啟動測(ce)量(liang)后發出聲光報警(jing);屏(ping)幕右下角處指示0%~99%表示測(ce)量(liang)進程。
測量中(zhong)按“確認(ren)”鍵取消測量,遇(yu)緊(jin)急情況立即(ji)關閉總電源。
3.10查看數據
顯示結果后,按鍵可查看其它數據,按鍵 存儲(chu)數(shu)據。按鍵 移動光標選擇printquit.
Print 打印當前數據。Quit 返回初始畫面。
正/反接線顯示數據如下:
儀器自動(dong)分(fen)辨電(dian)容、電(dian)感(gan)、電(dian)阻(zu)型(xing)試品(pin):電(dian)容型(xing)試品(pin)顯(xian)示(shi)Cx和tgδ;電(dian)感(gan)型(xing)試品(pin)顯(xian)示(shi)Lx;電(dian)阻(zu)型(xing)試品(pin)顯(xian)示(shi)Rx和附(fu)加Cx或Lx。自動(dong)選取(qu)顯(xian)示(shi)單位。
試品類型(xing)
顯示數據(ju)
備注
電容(rong)
Cx,tgδ,U,I,F1,F2
 
電感(gan)
Lx,U,I,F1,F2
電(dian)阻
Rx,U,I,F1,F2
Cx 試品電容量[1μF=1000nF納(na)法(fa) / 1nF=1000pF],如顯(xian)示10.00nF即10000pF
tgδ    介損因(yin)數(shu)[1%=0.01]
Lx 試(shi)品(pin)電感(gan)量(liang)[1MH兆亨=1000kH / 1kH=1000H]
Rx 試品電阻值(zhi)[1MΩ=1000kΩ / 1kΩ=1000Ω]
U   試驗電壓[1kV=1000V / 1V=1000mV]
I   試品電(dian)流[1A=1000mA / 1mA=1000μA]
F1 頻率(lv)[Hz],頻率(lv)顯(xian)示實際(ji)頻率(lv)
F2 頻(pin)率(lv)[Hz],頻(pin)率(lv)顯示實(shi)際頻(pin)率(lv)
CVT自激法測量顯示數據為:C1、tgδ / C2、tgδ
按測量接線,與試品輸入Cx插座連接的定義為C1,與高壓線連接的為C2
3.11與計算機連接(jie)
連接好計(ji)算機(ji)后,可以上(shang)傳數據(ju)等功(gong)能。
3.12參考接(jie)線
3.12.1正(zheng)接線、內標準電(dian)容、內高壓(常規正(zheng)接線):
 
 
 
 
 
 
 
 
3.12.2反接(jie)線(xian)、內標準電容、內高壓(常規反接(jie)線(xian)):
 
 
 
 
 
 
 
 


 

3.12.3正接線(xian)、外標準電容、內高壓:
 
 
 
 
 
 
 


 

3.12.4反接線、外標(biao)準電容、內高壓:
 
 
 
 


 

3.12.5正接線、內(nei)標(biao)準電容、外高壓:
 
 
 
 
 
 
 
 


 

3.12.6反(fan)接線、內標準電(dian)容、外高壓:
 
 
 
 
 
 
 


 

3.12.7正接線、外(wai)標準電(dian)(dian)容、外(wai)高(gao)壓(高(gao)電(dian)(dian)壓介損):
 
 
 
 
 
 


 

3.12.8反接(jie)線、外標準電容、外高壓:
 
 
 
3.12.9 CVT自(zi)激法測(ce)量:
CVT自激法可按下圖接線。如果C1是單節電容,母線不能接地;如果C1是多節電容,母線可接地,C11和C12可用常規正反接線測量,C13和C2用自激法測量。
 
 
 
 
 
 
 
 


 

CVT自激法測量中,儀器先測量C1,然后自動倒線測量C2,并自動校準分壓影響。
應注意,高壓線應懸空不能接觸地面,否則其對地附加介損會引起誤差,可用細電纜連接高壓插座與CVT試品并吊起。強烈建議使用高壓插座使用的高壓線用黑色Cx線。
3.13附加功能(neng)
1.光標在 電壓:10kV上面時候,按“確認”鍵在儀器屏幕的左下角會出現 圖標,代表測試結束自動打印。如果再按確認鍵,圖標消失,代表測試結束必須手動才能打印。
2.光標在 變頻 上面時候,在反接線,內Cn,內Un,情況下,按確認鍵在儀器屏幕右下角會出現 圖標,代表反接線低壓屏蔽測試。如果再按確認鍵,圖標消失,代表取消反接線低壓屏蔽。
3.光標在 反接 上面時候,按確認鍵則測試打印機,換紙。
4.光標在 啟動 上面時候,按減小鍵則代表取出存儲的數據。
5.測試完畢,如果按減小鍵,則代表存儲測試的數據
4. 新增功能使用(yong)說明
4.1 反接線低(di)壓屏蔽
光標在 變頻 上面時候,在反接線,內Cn,內Un,情況下,按確認鍵在儀器屏幕右下角會出現 圖標,啟動反接線低壓屏蔽功能。
可在220kVCVT母線接地情況下,對C11進行不拆線10kV反接線介損測量。如下圖所示:母線掛地線,C11上端不拆線,C11下端接高壓線芯線,C2末端δ和X接Cx芯線。這樣C12和C2被低壓屏蔽,儀器采用反接線/10kV/M測量方式,測量出C11
 
 
 
 
 
 
 
 
 
 


 

5. 新(xin)增功(gong)能使用說(shuo)明(ming)
5.1 配置熱(re)敏打印機(ji):在打印時更加迅速、無噪音。儀器能自動根據環境溫度,調節打印質量,確保打印更加清晰。
5.2 放電提示
儀器在測試過程中自動監測接線情況,如果在回路中有接觸不良或打火放電的情況,儀器會在屏幕左側顯示    和放電次數,般情況下放電次數不大于20。
5.3 CVT變比測試
儀器高壓線的芯線紅夾子接CVT的上端,母線拆地。CVT下端接地,低壓線紅黑夾子接二次繞組,注意:如果測試角度接近180度,應將紅黑夾子顛倒。
5.4 反接線低壓屏蔽功能,次接線可同(tong)時(shi)測出C1和C2的電容量和介損
光標在 變頻 上面時候,在反接線,內Cn,內Un,情況下,按確認鍵在儀器屏幕右下角會出現 圖標,啟動反接線低壓屏蔽功能。
 
 
 
 
 
 
 
 


 

打開反接線低壓屏蔽,可在上端電容C1不拆母線的情況下,對其進行不拆線10kV反接線介損測量。如下圖所示:母線掛地線,C1上端不拆線,C1下端接高壓線芯線,C2末端接Cx芯線。儀器采用反接線/10kV/M測量方式,可同時測出C11和下端屏蔽部分的電容量和介損值
 
 
 
 
 
 


 

6 現場試驗(yan)注意(yi)事項
如果使用中出現(xian)測試數據明顯不合理,請從(cong)以下方面查找原因:
6.1搭鉤(gou)接觸不良
現場測量使(shi)用搭鉤連(lian)接試(shi)品(pin)時(shi),搭鉤務必與試(shi)品(pin)接觸(chu)良好,否(fou)則接觸(chu)點放(fang)電(dian)會引(yin)起數據嚴(yan)重波動!尤其是引(yin)流線氧化層太厚,或風吹線擺動,易造成接觸(chu)不良。
6.2接地接觸不良
接(jie)地不良會引起儀器(qi)保(bao)護或數據(ju)嚴重波動(dong)。應刮凈接(jie)地點(dian)上的(de)油(you)漆和銹蝕,務必保(bao)證0電阻接(jie)地!
6.3直(zhi)接(jie)測量CVT或末端屏蔽法測量電磁式PT
直接測量CVT的(de)下節耦(ou)合電容會(hui)出現負介(jie)損,應改用自激法(fa)。
用末端(duan)屏蔽法測量(liang)(liang)電(dian)磁式PT時,由于受潮引起“T形網絡干(gan)擾”出現負介(jie)損(sun),吹干(gan)下(xia)面(mian)三(san)裙瓷套(tao)和(he)接線(xian)端(duan)子(zi)盤即可。也可改用常規(gui)法或末端(duan)加(jia)壓法測量(liang)(liang)。
6.4空(kong)氣濕度過(guo)大
空氣濕度大使介損測量值異常增大(或減(jian)小甚為(wei)負)且(qie)不穩定(ding),必要時可(ke)加屏(ping)蔽環。因人(ren)為(wei)加屏(ping)蔽環改變了試品電場分布,此法(fa)有爭(zheng)議,可(ke)參照有關規程(cheng)。
6.5發電機供(gong)電
發電機供電時輸入(ru)頻率(lv)不穩(wen)定,可采用(yong)定頻50Hz模式工作。
6.6測(ce)試線
由于長期使用,易造成測(ce)試線隱(yin)性斷路,或(huo)芯(xin)線和(he)屏蔽短路,或(huo)插頭(tou)接觸(chu)不良,用戶(hu)應經常維(wei)護測(ce)試線;
測試(shi)標(biao)準電(dian)容(rong)試(shi)品(pin)時,應使用(yong)全屏(ping)蔽插頭連(lian)接,以消除附加雜(za)散電(dian)容(rong)影響,否則不能反映出儀器精度;
自激法測(ce)量(liang)CVT時,非的高壓線應吊起懸空(kong),否則對地附加雜散電容和(he)介損會引起測(ce)量(liang)誤差。
6.7工作(zuo)模式(shi)選(xuan)擇
接好(hao)線(xian)后(hou)請選擇正(zheng)確(que)的測量(liang)工作模式(正(zheng)、反和CVT),不可(ke)選錯。特別是干擾(rao)環境下應選用變頻抗干擾(rao)模式。
6.8試(shi)驗方法影響(xiang)
由于(yu)介損(sun)測量受試(shi)驗方(fang)法影響較(jiao)大,應區分是(shi)試(shi)驗方(fang)法誤差還是(shi)儀器誤差。出現問題(ti)時可先(xian)檢查(cha)接(jie)線,然后檢查(cha)是(shi)否(fou)為儀器故(gu)障。
6.9儀(yi)器故障
用(yong)萬用(yong)表測量下測試線是(shi)否(fou)斷路,或芯線和屏蔽(bi)是(shi)否(fou)短路;輸(shu)入(ru)電(dian)源220V過高或過低;接地是(shi)否(fou)良好。
用(yong)正、反接線(xian)測下(xia)標準電容器或已知(zhi)容量和介損的電容試品(pin),如果結果正確(que),即(ji)可(ke)判斷儀器沒(mei)有(you)問(wen)題(ti);
拔下(xia)所有測試(shi)(shi)導線,進(jin)行空(kong)試(shi)(shi)升壓,若不能正常工作,儀器可能有故障(zhang)。
啟(qi)動CVT測量后測量低(di)壓(ya)輸出(chu),應出(chu)現2~5V電壓(ya),否(fou)則(ze)儀(yi)器有故障。
 
7. 儀器檢(jian)定
7.1用標準損耗器檢定
用帶(dai)插頭的屏蔽電(dian)(dian)纜連接標準損(sun)耗器。如果不能保(bao)證(zheng)標準損(sun)耗器的精(jing)度,應使用比對(dui)(dui)法(fa)檢(jian)定,建議用2801電(dian)(dian)橋或(huo)其(qi)它精(jing)密電(dian)(dian)橋作比對(dui)(dui)標準。
儀器應(ying)選用“內標(biao)準”和(he)“RC串聯試品”,可選擇工頻 50Hz或(huo)定頻50Hz頻率模式。
7.2用QSJ3檢定
使用帶插頭的屏蔽電(dian)纜連接(jie)(jie)QSJ3,選(xuan)擇“正接(jie)(jie)/ 外Cn / 外Un式測量,電(dian)流比為CxCn,Cn可置(zhi)入適當值。
7.3抗干擾能力(li)
設置個回(hui)路向儀器(qi)注入(ru)定量的干擾(rao)電流。
注意:
1)應考(kao)慮到該(gai)回路(lu)可能成為試品的部分(fen)。
2)儀(yi)器(qi)啟動后會使220V供電(dian)電(dian)路帶有測量頻率(lv)分量,如(ru)果該頻率(lv)分量又通(tong)過(guo)干擾(rao)電(dian)流進(jin)入儀(yi)器(qi),則無法檢驗儀(yi)器(qi)的抗干擾(rao)能(neng)力。
3)不建議用臨(lin)近高壓導體(ti)施加干擾(rao),因為這樣很容易產(chan)(chan)生近距離放電(dian),這種放電(dian)電(dian)阻是非線性的,容易產(chan)(chan)生同頻干擾(rao)。
8. 儀器工作原理簡(jian)介
8.1儀器結(jie)構
 
 
 
 
 
儀器結(jie)構框(kuang)圖(tu)
測(ce)量(liang)電路:傅(fu)立葉變(bian)換、復數運(yun)算等全(quan)部計算和(he)量(liang)程切換、變(bian)頻電源(yuan)控制等。
控制面板(ban):打印(yin)機、鍵盤、顯示(shi)和通訊中轉。
變頻電源:采用SPWM開關電路產生大功率正(zheng)弦波穩壓輸出。
升(sheng)(sheng)壓(ya)變(bian)(bian)壓(ya)器:將變(bian)(bian)頻電源輸出升(sheng)(sheng)壓(ya)到測量電壓(ya),zui大無功輸出2kVA / 1分(fen)鐘。
標準電(dian)容器:內Cn,測(ce)量基(ji)準。
Cn電(dian)流檢(jian)測:用于檢(jian)測內/外標準(zhun)電(dian)容器(qi)電(dian)流。
Cx正(zheng)接線電流檢測(ce):只用(yong)于正(zheng)接線測(ce)量。
Cx反接線(xian)電流檢(jian)測:只用于(yu)反接線(xian)測量。
反接(jie)線數字隔(ge)離通訊:用(yong)高速數字隔(ge)離通訊電路,將(jiang)反接(jie)線電流信號送到低壓側。
8.2工作原理
啟動(dong)測(ce)量(liang)(liang)(liang)后(hou)高壓(ya)(ya)設定(ding)值送(song)到(dao)變(bian)頻(pin)(pin)電(dian)(dian)(dian)(dian)源(yuan)(yuan),變(bian)頻(pin)(pin)電(dian)(dian)(dian)(dian)源(yuan)(yuan)用PID算(suan)(suan)法將(jiang)輸(shu)出緩速(su)調整(zheng)到(dao)設定(ding)值,測(ce)量(liang)(liang)(liang)電(dian)(dian)(dian)(dian)路將(jiang)實(shi)測(ce)高壓(ya)(ya)送(song)到(dao)變(bian)頻(pin)(pin)電(dian)(dian)(dian)(dian)源(yuan)(yuan),微調低壓(ya)(ya),實(shi)現準確高壓(ya)(ya)輸(shu)出。根(gen)據正(zheng)/反接線和內/外標準電(dian)(dian)(dian)(dian)容的設置,測(ce)量(liang)(liang)(liang)電(dian)(dian)(dian)(dian)路根(gen)據試(shi)驗電(dian)(dian)(dian)(dian)流自(zi)動(dong)選擇輸(shu)入并切換量(liang)(liang)(liang)程,測(ce)量(liang)(liang)(liang)電(dian)(dian)(dian)(dian)路采用傅立葉變(bian)換濾掉(diao)干擾,分離出信號基波(bo),對標準電(dian)(dian)(dian)(dian)流和試(shi)品(pin)電(dian)(dian)(dian)(dian)流進行矢量(liang)(liang)(liang)運算(suan)(suan),幅值計(ji)(ji)算(suan)(suan)電(dian)(dian)(dian)(dian)容量(liang)(liang)(liang),角差計(ji)(ji)算(suan)(suan)tgδ。反復進行多次測(ce)量(liang)(liang)(liang),經過排序選擇個中間結(jie)(jie)果(guo)。測(ce)量(liang)(liang)(liang)結(jie)(jie)束,測(ce)量(liang)(liang)(liang)電(dian)(dian)(dian)(dian)路發(fa)出降(jiang)壓(ya)(ya)指(zhi)令變(bian)頻(pin)(pin)電(dian)(dian)(dian)(dian)源(yuan)(yuan)緩速(su)降(jiang)壓(ya)(ya)到(dao)0。
CVT測量:CVT隔離開關斷開,低壓隔離開關接通輸出低壓。測量C2時,CVT倒線開關接通,C2接入試品通道,用C1作標準電容測量C2
9. 變頻測量討論(lun)
9.1變頻測量
干擾(rao)(rao)十(shi)分嚴(yan)重(zhong)時(shi),變(bian)頻測量(liang)(liang)(liang)能得到準確可靠的結果(guo)。例如用55Hz測量(liang)(liang)(liang)時(shi),測量(liang)(liang)(liang)系統只允(yun)許55Hz信號通過(guo),50Hz干擾(rao)(rao)信號被有效抑(yi)制,原因在于測量(liang)(liang)(liang)系統很(hen)容易(yi)區別不同頻率,由下述簡單計算可以說明選(xuan)頻測量(liang)(liang)(liang)的效果(guo):
兩個頻(pin)率(lv)相差1倍的正弦波疊加(jia)到起(qi),高頻(pin)的是干(gan)擾,幅(fu)度為低頻(pin)的10倍:
Y=1.234sin(x+5.678°)+12.34sin(2x+87.65°)
在(zai)x=0/90/180/270°得到4個測量值
Y0=12.4517,Y1= -11.1017,Y2=12.2075,Y3= -13.5576,
計算A=Y1 - Y3=2.4559,B=Y0 - Y2=0.2442,則:
φ=tg-1(B/A)=5.678° V=   A2+B2 / 2=1.234
這剛好是低頻(pin)部分的相位(wei)和幅度,干擾被(bei)抑制。實際(ji)波形的測(ce)量點多達(da)數萬,計算量很大,結(jie)果反映(ying)了(le)波形的整體特征。
9.2頻率(lv)和介損(sun)的關系
介損有RC串聯和并聯兩種(zhong)理想模型(xing):串聯模型(xing)tgδ=2πfRC,并聯模型(xing)tgδ=1/(2πfRC),tgδ分別隨頻率f成正(zheng)比和反(fan)比。如圖所示,f對*正(zheng)比和*反(fan)比兩種(zhong)模型(xing)影響較大。但實(shi)際(ji)電容器是多(duo)種(zhong)模型(xing)交織的混(hun)合模型(xing),此時f的影響就(jiu)小。
 
        tgδ              ;  串聯模型            tgδ
               ;             介損恒(heng)定
 


 

           ;                 實際試品(pin)
 
                            并(bing)聯模型
                            f                                   f
        低頻介損曲線(<1kHz)          ;&nbsp;  高頻介損曲線或低頻電路諧振
9.3自動(dong)變(bian)頻(pin)與50Hz等效
儀器采用自動變頻在干擾頻率50Hz兩側(45Hz和55Hz)各測(ce)個點,然后(hou)推算50Hz頻率(lv)下(xia)數(shu)據(ju)。除多個元(yuan)件電路的(de)低頻諧振(zhen)外,單個試品中(zhong)的(de)介質不(bu)可能在低頻引(yin)起能量吸收峰(feng),工頻附近(jin)(jin)介損(sun)總是隨頻率(lv)單調(diao)變化(hua)的(de)。因(yin)此(ci)這種測(ce)量方法不(bu)會(hui)帶來明顯(xian)誤差。實際上,平均前(qian)的(de)兩個介損(sun)值已十(shi)分(fen)接近(jin)(jin),即(ji)使不(bu)平均也*有參考價(jia)值。目前(qian),變頻介損(sun)儀已成為介損(sun)測(ce)量的(de)常規儀器(qi),其(qi)優(you)異(yi)的(de)抗干擾能力和準(zhun)確度已經得到認(ren)可。
 
 
 
 
 
變頻抗干擾介質損耗測試儀是發電廠、變電站等現場全自動測量各種高壓電力設備介損正切值及電容量的高精度儀器。
儀(yi)器為體(ti)化結(jie)構,內置介損電橋、變(bian)頻電源、試驗變(bian)壓器和(he)標準電容器等(deng)。采(cai)用變(bian)頻抗干擾和(he)傅立葉變(bian)換數字濾(lv)波(bo)技術,全(quan)自(zi)動(dong)智能化測量(liang)(liang),強干擾下測量(liang)(liang)數據非(fei)常穩(wen)定。測量(liang)(liang)結(jie)果由大屏幕液晶顯示,自(zi)帶微型打(da)印機可打(da)印輸出。
 
產(chan)品特點
KTJSYBP變頻抗干擾介質損耗測試儀采用變頻抗干擾技術,在200%干擾下仍能準(zhun)確測(ce)量,測(ce)試(shi)數(shu)據穩定,適(shi)合在現場做抗干擾介損試(shi)驗(yan)。
高精(jing)度測量
變頻(pin)抗干擾(rao)介質損耗(hao)測(ce)試儀(yi)采用數(shu)字波形分析和電橋自校準等技(ji)術,配合高精度三(san)端標準電容器,實現高精度介損測量(liang)。
變頻抗干(gan)擾(rao)介質(zhi)損(sun)耗(hao)測試(shi)儀所(suo)有量程輸入電(dian)阻低于,消除了測(ce)量電纜附加電容的影(ying)響。
多級(ji)安全保(bao)護,確保(bao)人身(shen)和設備安全
高(gao)壓(ya)保(bao)護:試品短路、擊(ji)穿或高(gao)壓電流波動,能以(yi)短路方式(shi)高(gao)速切斷輸(shu)出。
低壓(ya)保護:誤接380V、電(dian)源(yuan)波動或突然斷電(dian),啟動保護,不會引起過電(dian)壓。
接地(di)保護(hu):儀器接地不良(liang)使外殼帶危險(xian)電(dian)壓時,啟動接地保護(hu)。
CVT高壓電(dian)(dian)壓和電(dian)(dian)流(liu)(liu)、低壓電(dian)(dian)壓和電(dian)(dian)流(liu)(liu)四個保護(hu)限,不(bu)會損壞設備;誤選菜(cai)單不(bu)會輸出(chu)激(ji)磁電(dian)(dian)壓。CVT測量時無10kV高壓輸(shu)出。
防誤(wu)操作:兩級電源開關;電壓、電流實(shi)時監示;多(duo)次按(an)鍵確(que)認;接線(xian)端子高(gao)/低壓分明;緩速升壓,可迅速降壓,聲光報警。
容(rong)升測量大容量試品時會出現電壓抬高的容升效應(ying),儀器能(neng)自動跟蹤輸出電(dian)壓,保持(chi)試驗電(dian)壓恒定。
抗震(zhen)性能:儀(yi)器采用*抗震(zhen)設(she)計,可耐受(shou)強(qiang)烈長途運輸(shu)震(zhen)動(dong)、顛簸而不會(hui)損(sun)壞(huai)。
高壓電纜:為(wei)耐高壓絕(jue)緣(yuan)導(dao)線,可拖地使用(yong)。
功(gong)能(neng)強大,產品系列化
本(ben)起有兩種型號: EF型。
1具有(you)正/反接(jie)線,內/外標準電(dian)容,內/外高(gao)壓多種(zhong)工作模式,體化結(jie)構,可做各種(zhong)常規介(jie)損試驗,不需外接任何(he)輔助設備。
2)液晶顯示,菜(cai)單操作,測試(shi)(shi)數據(ju)豐富,自(zi)動(dong)分辨電容、電感、電阻型試(shi)(shi)品(pin),自(zi)帶微型打(da)印機可打(da)印輸(shu)出。
3)具有外(wai)(wai)接(jie)(jie)(jie)標準電(dian)容器(qi)接(jie)(jie)(jie)口,可(ke)外(wai)(wai)接(jie)(jie)(jie)油(you)杯做(zuo)(zuo)精密絕(jue)緣油(you)介(jie)損試(shi)驗,可(ke)外(wai)(wai)接(jie)(jie)(jie)固體材料(liao)測(ce)量電(dian)極做(zuo)(zuo)精密絕(jue)緣材料(liao)介(jie)損試(shi)驗,也可(ke)外(wai)(wai)接(jie)(jie)(jie)高壓標準電(dian)容器(qi)做(zuo)(zuo)高電(dian)壓介(jie)損試(shi)驗。
4)自動識別50Hz / 60Hz系統電(dian)(dian)源,并支持發電(dian)(dian)機供電(dian)(dian),即使頻率波動大,也可正常測量。
5)內置串(chuan)聯和并聯兩種介損測量模(mo)型(xing),方便儀器檢(jian)定。
6)可存儲255組測(ce)量數(shu)據(ju)。
7CVT自激法測量時,C1/C2可次接(jie)線同時測出(chu),自(zi)動(dong)補償母線接(jie)地和標準電容器的分(fen)壓影響,無須換線和外(wai)接(jie)任何(he)配件。
8)中文圖文菜(cai)單(dan),大(da)屏(ping)幕背光LCD顯示更清晰,電(dian)流電(dian)壓(ya)實時(shi)監(jian)視。
9)優化的電路設計(ji),使正(zheng)/反接線(xian)的準(zhun)確度和穩定性致。
10)自動識別(bie)外接高壓試驗電源頻率(lv)40Hz70Hz,支持工頻電源、變(bian)頻電源和串聯諧振電源做大容量高電壓介(jie)損(sun)試(shi)驗(yan)。
11)具有反接線低壓(ya)屏蔽功能(neng),在220kVCVT母線(xian)接地情況下,對C11可進行不拆線10kV反接(jie)線介損測量。
12)帶(dai)計算機(ji)接口(kou)。通過(guo)該接口(kou),實現測量、數據處理和報表輸出,也可實現儀(yi)器(qi)內部測量軟(ruan)件升級。可集(ji)成到綜合高壓試驗車(che)上。
F型(xing):除具備E型全部功能外,
(1)配置熱敏打印機,使打印更加快捷、無噪音和清晰。
(2)增加回路接觸不良放電提示功能,以方便判別接線是否可靠。
(3)增強反接線低壓屏蔽功能,可次接線同時測出兩個電容的電容量和介損值。
(4)增加CVT變比功能,可測量(liang)CVT變比和相位誤(wu)差。
供貨范圍
1)儀器(qi)主(zhu)機        &nbsp;    &nbsp;            2)使用說明書和產品(pin)合格證
3)測試(shi)電纜線(xian)         &nbsp;        4)電(dian)源線
5)備用色帶(dai)、打(da)印紙和保險管    6)其它詳見(jian)《裝箱單(dan)》
1主要功能
準確度:         ;  Cx:      ±(讀數×1%+1pF
tgδ:     ±(讀(du)數×1%+0.00040
抗干擾指標:變頻抗干擾,在200%干擾下仍能達到上述準確度
電容量范圍:      施(shi)高壓(ya):   3pF60000pF/10kV     60pF1μF/0.5kV
外(wai)高壓(ya):   3pF1.5μF/10kV   &nbsp;     60pF30μF/0.5kV
分辨率                 zui高0.001pF4位有效數字(zi)
tgδ范圍:   不(bu)限,分辨(bian)率0.001%,電(dian)(dian)容、電(dian)(dian)感(gan)、電(dian)(dian)阻三種(zhong)試品(pin)自動(dong)識別。
試驗(yan)電流范圍10μA
內施高(gao)壓:   設定電壓范圍:0.510kV
zui大輸出電流:200mA
升降壓(ya)方式:     連續(xu)平滑調節(jie)
電壓精度(du):   ±(1.5%×讀數+10V)
電壓分(fen)辨率:     1V
試驗頻(pin)率:   4550556065Hz單頻
45/55Hz55/65Hz47.5/52.5Hz自動(dong)雙變頻(pin)
頻率精度:   ±0.01Hz
外施(shi)高(gao)壓:   正接線時zui大試(shi)驗電(dian)流(liu)1A,工頻或變頻40-70Hz
反接線時zui大試驗(yan)電(dian)流10kV/1A,工頻或變頻40-70Hz
CVT自激法低壓輸出:輸(shu)出電壓350V,輸出電流330A
測量(liang)時間:   約(yue)40s,與測量方式有關
輸入電源:   180V270VAC50Hz/60Hz±1%,市電(dian)或發電(dian)機供電(dian)
計算機接口:      標準RS232接口
打印(yin)機:        ;   煒煌(huang)A7熱敏微型打印機
環境溫度:    -10℃~50℃
 
2面板介紹:
1高壓輸出(chu)插(cha)座(0.5~10kV,zui大200mA)
安裝位置:箱體前側面,外設保護門。
    能:內高壓輸出;檢測反接線試品電流;內部標準電容器的高壓端。
接線方法:插座1腳接高壓線芯線(紅夾子),2、3腳接高壓線屏蔽(黑夾子)。正接線時,高壓線芯線(紅夾子)和屏蔽(黑夾子)都可以用作加壓線;反接線時只能用芯線對試品高壓端加壓。如果試品高壓端有屏蔽極(如高壓端的屏蔽環)可接高壓屏蔽,無屏蔽時高壓屏蔽懸空。
注意事項:
(1)儀器測量電纜通用,建議用高壓線連接此插座。高壓插座和高壓線有危險電壓,禁止碰觸高壓插座、電纜、夾子和試品帶電部位!確認斷電后接線,測量時務必遠離!
(2)用標準介損器(或標準電容器)檢定反接線精度時,應使用全屏蔽插頭連接試品,否則暴露的芯線會引起誤差。
(3)應保證高壓線與試品高壓端0電阻連接,否則可能引起誤差或數據波動,也可能引起儀器保護。
(4)強干擾下拆除接線時,應在保持電纜接地狀態下斷開連接,以防感應電擊。
2.2試品輸入Cx插座(10μA~1A)
    能:正接線時輸入試品電流。
接線方法:插座1腳接測量線芯線(紅夾子),2、3腳接測量線屏蔽(黑夾子)。正接線時芯線(紅夾子)接試品低壓信號端,如果試品低壓端有屏蔽極(如低壓端的屏蔽環)可接屏蔽,試品無屏蔽時屏蔽懸空。
注意事項:
(1)測量中嚴禁拔下插頭,防止試品電流經人體入地!
(2)用標準介損器(或標準電容器)檢測儀器正接線精度時,應使用全屏蔽插頭連接試品,否則暴露的芯線會引起誤差。
(3)應保證引線與試品低壓端0電阻連接,否則可能引起誤差或數據波動,也可能引起儀器保護。
(4)強干擾下拆除接線時,應在保持電纜接地狀態下斷開連接,以防感應電擊。
2.3標準電容輸入Cn插(cha)座(10μA~1A)
    能:輸入外接標準電容器電流。
接線方法:與Cx插座類似,其區別在于:
 
(1)使用外部標準電容器時,應使用全屏蔽插頭連接。此方式常用于外接高電壓等級標準電容器,實現高電壓介損測量。
(2)菜單選擇“外Cn”方式。
(3)將外接標準電容器的C和tgδ置入儀器,實現Cx電容介損的值測量。
從原理上講,任何容量和介損的電容器,將參數置入儀器都可做標準電容器。不同的是標準電容器能提供更好的長期穩定性和精度。
(4)不管正接線還是反接線測量,標準電容器接線方式始終為正接線。
2.4 CVT自(zi)激法低壓輸出插座(3~50V,3~30A)
    能:由該插座和接地接線柱輸出CVT測量的低壓變頻激勵電源。
注意事項:
(1)因低壓輸出電流大,應采用儀器低阻線連接CVT二次繞組,接觸不良會影響測量。
(2)視CVT容量從菜單選擇合適的電壓電流保護限。
(3)啟動CVT測量時,輸出2~5V的試探電壓,若外部接線有錯會自動停機。若懷疑儀器故障,可測量有無該試探電壓。
(4)選擇正/反接線時,此輸出封閉。
2.5測量接(jie)地接(jie)線柱
它同外殼和電源插座地線連到起。
注意事項:
(1)盡管儀器有接地保護,但無論何種測量,儀器都應可靠獨立接地。
(2)保證0電阻接地。應仔細檢查接地導體不能有油漆或銹蝕,否則應將接地導體刮干凈。輕微接地不良可能引起誤差或數據波動,嚴重接地不良可能引起危險!
2.6電(dian)源輸(shu)入插座(180V~270V 50Hz/60Hz)
注意事項:
(1)KTJSYBPE變頻抗干擾介質損耗測試儀有快速斷電保護功能,低壓突然斷電時迅速以短路方式切斷高壓輸出。此功能要求儀器的低壓電源(插座、刀閘等)應可靠連接,否則超過數ms的斷電便會引起保護。
(2)輸入電壓大于270V(如誤接380V),儀器立即保護,切斷內部電源。保護后只有總電源開關燈亮,但屏幕無顯示。此時可檢查電源,重新開機。
(3)如果電壓過低,儀器無法輸出設定高壓,可用調壓器調整。
(4)儀器可以自動適應50Hz/60Hz電源頻率。
(5)采用發電機供電時,頻率波動大,且使用發電機的場合不存在干擾,可選擇“定頻”模式,以排除發電機供電頻率波動的影響。
2.7保險管座(zuo)
保險管座與低壓電源插座合為體,保險管規格 / 250V,尺寸φ5×20mm。
注意事項:應使用相同規格的保險絲。若換用備用保險絲后仍燒斷,可能儀器有故障,可通知廠家處理。
2.8總電(dian)源開關(guan)
打開總電源開關,先顯示儀器名稱和編號,數秒后自動進入測量菜單。關閉此開關,也同時關閉內部高壓系統電源,緊急情況應立即關閉此開關。
2.9按(an)鍵
(1)“移動光標,“和“修(xiu)改(gai)光標(biao)處內容,“確(que)定”用(yong)于確(que)認(ren)或停止。詳細功(gong)能見各型號儀器的“使用(yong)說(shuo)明(ming)”。注意:確定(ding)”是個鍵,不要當做兩個按鍵使用。
(2)測(ce)量(liang)過程中,按確(que)定鍵即終止測量。
2.11液(ye)晶顯(xian)示器(qi)
顯示菜單、測量結果或出錯信息。應避免長時間陽光爆曬,避免重壓。
2.12打印機
手動打印:顯示可打印數據時,按“打印”鍵打印。。
自動打印:菜單選擇自動打印后,測量結束即自動打印結果,之后可在遠處切斷儀器供電,使操作更加安全。
換紙和色帶:打印機為M150型微型打印機。打印紙寬44mm。換紙時要拉出打印機整體,將紙送入進紙口并按走紙鍵。換色帶時取下上蓋,色帶平直安裝。
    KTJSYBP變頻抗干(gan)擾介質損(sun)耗測試儀配置(zhi)熱敏打印(yin)機,使(shi)用寬度44mm熱敏打印(yin)紙(zhi)。換紙(zhi)時要打開打印(yin)機的紙(zhi)倉蓋板(ban),放入紙(zhi)卷并留(liu)少(shao)許部分(fen)在外面,然后關閉(bi)蓋板(ban)。
2.13通訊(xun)接口
    能:RS232接口,與PC機或筆記本電腦的串行通訊口連接。為保證通訊正常,雙方應設置相同的波特率和通訊地址。
通訊協議:儀器與PC機按規定協議通訊,實時操作儀器,實現數據存儲傳送等功能。
3.使(shi)用說(shuo)明(ming)
 
3.1對比度調節
液晶顯示屏的對比度已在出廠時校好,如果您感覺不夠清晰,可用如下方法調整:
按住(zhu)或(huo)不動(dong),再打開總電源開關,再按(an)調(diao)整顯示對(dui)比度,調(diao)整完(wan)畢(bi)按確定鍵(jian)退出(chu)。
3.2進入菜單
打開總電源開關后,先顯示開機畫面:

抗干擾
精(jing)密介損儀

 
 
 
 
 
 
 
然后自動進入測量菜單。

正接      &nbsp;    Cn
變(bian)頻  ;      &nbsp;  Un
        10kV
啟動
 

 
 
 
 
 
 
 
3.3選擇接線(xian)方式
光標在“正接”,按↑↓選擇(ze)“正接&rdquo;、“反接”和“CVT”測量方(fang)式。
3.4選擇內(nei)、外(wai)標準電容
光標(biao)在,按↑↓選擇“內標(biao)準(zhun)(zhun)”“外(wai)標(biao)準(zhun)(zhun)”,表示使用內或外(wai)接標(biao)準(zhun)(zhun)電容。通常可用內部(bu)標(biao)準(zhun)(zhun)作正、反(fan)接線測(ce)量和CVT自激法測(ce)量,高電壓(ya)介損選用外(wai)標(biao)準(zhun)(zhun)方(fang)式,需要將外(wai)接電容參(can)數(shu)置入儀(yi)器(qi)。光標(biao)在“外(wai)cn”,按(an)住(zhu)“啟(qi)停”鍵1s以上出現外(wai)標(biao)準(zhun)(zhun)電容值,按(an)↑↓鍵 可(ke)以修改此數值。修改完畢按(an)住“啟停”鍵1s左右,聽到(dao)蜂鳴器(qi)響聲,松開鍵盤即可(ke)保存(cun)。
3.5選擇(ze)試驗頻率
3.5.1開機默認頻率
光標在 “變頻”,表示45/55Hz自動變頻。儀器自動用45Hz和55Hz各測量次,然后計算50Hz下無干擾時數據。開機自動默認為該方式,建議使用。
3.5.2選擇更多頻率
光標在(zai)“變頻(pin)”,按住“啟停”鍵1s以上(shang)切(qie)換到(dao)全頻(pin)率(lv)選(xuan)擇(ze),按↑↓鍵(jian)循環(huan)顯(xian)示(shi)“45Hz / 50Hz / 55Hz / 60Hz / 65Hz / 50±5Hz / 60±5Hz / 50±2.5Hz”:
“50Hz”:為工(gong)頻(pin)測(ce)量,此設置不能抗干擾,在試驗室內測(ce)量或校驗時選用。
“45/55/60/65Hz”:為單頻率(lv)(lv)測量,研究不同頻率(lv)(lv)下介(jie)損的變化時(shi)選(xuan)用。
“50±5Hz”:為45/55Hz自動變頻,適(shi)合50Hz電(dian)網工頻干(gan)擾下測(ce)量。
“60±5Hz”:為55/65Hz自動變頻(pin),適合60Hz電網工頻(pin)干擾(rao)下測量。
“50±2.5”:為47.5/52.5Hz自動變(bian)頻(pin),適合50Hz電網工頻(pin)干(gan)擾下(xia)測量。
按住“啟停”鍵1s以上取消全頻率選擇。
3.6選擇試(shi)驗高(gao)壓
3.6.1正/反接線方式下選擇(ze)高(gao)壓
光標在10kV,按↑↓鍵循環顯示試驗高壓“0.5 /0.6 /0.8 /1 /1.5 /2 /2.5 /3 /3.5 /4 /4.5 /5 /5.5 /6 /6.5 /7 /7.5 /8 /8.5 /9 /9.5 /10kV”。應根據高壓試驗規程選擇試驗高壓。
啟動測量后,該處顯示測量高壓.下方顯示In=158uA    Ix=10mA
In=158uA 表示流(liu)過標準電容的(de)電流(liu),單位為 uA 。
Ix=10mA 表(biao)示流(liu)過試品的電流(liu),單位為 mA 。
如果In=000 uA ,表示內部高壓沒有輸出,或儀器有問題。請先查看屏幕是否選擇為內Un,內Cn
3.6.2 CVT自(zi)激法接線方式下選擇高壓
CVT自激法測量必須使用內部高壓電源,由機內提供激勵電壓,由“CVT1”和“CVT2”輸出。通常測量C1時低壓激勵電壓可達20V,測量C2時低壓激勵電流可達1。般可設高壓電壓1.5~2kV。
3.7自動打印
光標在10KV,按“確認”鍵可顯示或取消屏幕左下角處打印機圖標      ,有此圖標表示測量結束自動打印。
 
3.8啟(qi)動(dong)測量
光標在啟動,按住“確認”鍵1s以上啟動測量。
啟動測量后發出聲光報警;屏幕右下角處指示0%~99%表示測量進程。
測量中按“確認”鍵取消測量,遇緊急情況立即關閉總電源。
3.10查看數據
顯(xian)示結果后,按鍵可(ke)查看(kan)其它(ta)數據(ju),按鍵(jian) 存(cun)儲(chu)數據。按(an)鍵(jian) 移動光標選擇(ze)print或 quit.
Print 打印當前數據。Quit 返回初始(shi)畫面。
正/反接線顯示數據如下:
儀器自動分辨電容、電感、電阻型試品:電容型試品顯示Cx和tgδ;電感型試品顯示Lx;電阻型試品顯示Rx和附加Cx或Lx。自動選取顯示單位。
試品(pin)類型
顯(xian)示(shi)數據
備注
電容
Cx,tgδ,U,I,F1,F2
 
電感(gan)
Lx,U,I,F1,F2
電阻
Rx,U,I,F1,F2
Cx 試品電容量(liang)[1μF=1000nF納(na)法 / 1nF=1000pF],如顯(xian)示(shi)10.00nF即10000pF
tgδ    介損因數[1%=0.01]
Lx 試品電感(gan)量(liang)[1MH兆(zhao)亨(heng)=1000kH / 1kH=1000H]
Rx 試品電阻值(zhi)[1MΩ=1000kΩ / 1kΩ=1000Ω]
U   試驗電壓[1kV=1000V / 1V=1000mV]
I   試品電流[1A=1000mA / 1mA=1000μA]
F1 頻(pin)率(lv)[Hz],頻(pin)率(lv)顯示實際頻(pin)率(lv)
F2 頻率(lv)[Hz],頻率(lv)顯示實際(ji)頻率(lv)
CVT自激法測量顯示數據為:C1、tgδ / C2、tgδ
按測量接線,與試品輸入Cx插座連接的定義為C1,與高壓線連接的為C2
3.11與計算機連接
連接好計算機后,可以上傳數據等功能。
3.12參考接線
3.12.1正接線、內標準電容、內高壓(常規正接線):
 
 
 
 
 
 
 
 
3.12.2反接線、內(nei)標準電容、內(nei)高壓(常規反接線):
 
 
 
 
 
 
 
 

 
3.12.3正接線、外(wai)標(biao)準電容、內高壓:
 
 
 
 
 
 
 

 
3.12.4反接線、外標(biao)準電容、內(nei)高壓:
 
 
 
 

 
3.12.5正接線、內標準電容、外高壓(ya):
 
 
 
 
 
 
 
 

 
3.12.6反接線、內標準(zhun)電容、外(wai)高壓(ya):
 
 
 
 
 
 
 

 
3.12.7正接線、外標(biao)準電容、外高壓(高電壓介損):
 
 
 
 
 
 

 
3.12.8反接線、外標準電容、外高壓:
 
 
 
3.12.9 CVT自(zi)激法測量:
CVT自激法可按下圖接線。如果C1是單節電容,母線不能接地;如果C1是多節電容,母線可接地,C11和C12可用常規正反接線測量,C13和C2用自激法測量。
 
 
 
 
 
 
 
 

 
CVT自激法測量中,儀器先測量C1,然后自動倒線測量C2,并自動校準分壓影響。
應注意,高壓線應懸空不能接觸地面,否則其對地附加介損會引起誤差,可用細電纜連接高壓插座與CVT試品并吊起。強烈建議使用高壓插座使用的高壓線用黑色Cx線。
3.13附加功能
1.光標在 電壓:10kV上面時候,按“確認”鍵在儀器屏幕的左下角會出現圖標,代表測試結束自動打印。如果再按確認鍵,圖標消失,代表測試結束必須手動才能打印。
2.光標在 變頻 上面時候,在反接線,內Cn,內Un,情況下,按確認鍵在儀器屏幕右下角會出現圖標,代表反接線低壓屏蔽測試。如果再按確認鍵,圖標消失,代表取消反接線低壓屏蔽。
3.光標在 反接 上面時(shi)候,按確認鍵則測(ce)試打印機,換紙。
4.光(guang)標在 啟動 上面時(shi)候,按(an)減(jian)小(xiao)鍵則代表(biao)取出存儲的數據。
5.測(ce)(ce)試完畢,如果(guo)按減小鍵,則代表存(cun)儲測(ce)(ce)試的數據
4. 新增功能(neng)使(shi)用說(shuo)明
4.1 反接線低壓屏蔽(bi)
光標在 變頻 上面時候,在反接線,內Cn,內Un,情況下,按確認鍵在儀器屏幕右下角會出現圖標,啟動反接線低壓屏蔽功能。
可在220kVCVT母線接地情況下,對C11進行不拆線10kV反接線介損測量。如下圖所示:母線掛地線,C11上端不拆線,C11下端接高壓線芯線,C2末端δ和X接Cx芯線。這樣C12和C2被低壓屏蔽,儀器采用反接線/10kV/M測量方式,測量出C11
 
 
 
 
 
 
 
 
 
 

 
5. 新增功能使用(yong)說明
5.1 配置熱敏打(da)印機:在打印時更加迅速、無噪音。儀器能自動根據環境溫度,調節打印質量,確保打印更加清晰。
5.2 放電提示
儀器在測試過程中自動監測接線情況,如果在回路中有接觸不良或打火放電的情況,儀器會在屏幕左側顯示    和放電次數,般情況下放電次數不大于20。
5.3 CVT變比測試
儀器高壓線的芯線紅夾子接CVT的上端,母線拆(chai)地(di)。CVT下端接(jie)(jie)地(di),低壓線紅黑(hei)夾(jia)子(zi)(zi)接(jie)(jie)二次繞組,注(zhu)意(yi):如果測(ce)試角度接(jie)(jie)近180度,應將(jiang)紅黑(hei)夾(jia)子(zi)(zi)顛(dian)倒。
5.4 反接線低壓(ya)屏(ping)蔽功能,次接線可同時測出(chu)C1和C2的電容量和介損
光標在 變頻 上面時候,在反接線,內Cn,內Un,情況下,按確認鍵在儀器屏幕右下角會出現圖標,啟動反接線低壓屏蔽功能。
 
 
 
 
 
 
 
 

 
打開反接線低壓屏蔽,可在上端電容C1不拆母線的情況下,對其進行不拆線10kV反接線介損測量。如下圖所示:母線掛地線,C1上端不拆線,C1下端接高壓線芯線,C2末端接Cx芯線。儀器采用反接線/10kV/M測量方式,可同時測出C11和下端屏蔽部分的電容量和介損值
 
 
 
 
 
 

 
6 現(xian)場試驗(yan)注意(yi)事(shi)項(xiang)
如果使用中出現測試數據明顯不合理,請從以下方面查找原因:
6.1搭(da)鉤(gou)接觸不良
現場測量使用搭鉤連接試品時,搭鉤務必與試品接觸良好,否則接觸點放電會引起數據嚴重波動!尤其是引流線氧化層太厚,或風吹線擺動,易造成接觸不良。
6.2接地接觸不良
接地不良會引起儀器保護或數據嚴重波動。應刮凈接地點上的油漆和銹蝕,務必保證0電阻接地!
6.3直(zhi)接(jie)測量CVT或末端屏蔽(bi)法測量電磁式PT
直接測量CVT的下節耦合電容會出現負介損,應改用自激法。
用末端屏蔽法測量電磁式PT時,由于受潮引起“T形網絡干擾”出現負介損,吹干下面三裙瓷套和接線端子盤即可。也可改用常規法或末端加壓法測量。
6.4空氣(qi)濕度過(guo)大
空氣濕度大使介損測量值異常增大(或減小甚為負)且不穩定,必要時可加屏蔽環。因人為加屏蔽環改變了試品電場分布,此法有爭議,可參照有關規程。
6.5發電機供(gong)電
發電機供電時輸入頻率不穩定,可采用定頻50Hz模式工作。
6.6測試線(xian)
由于長期使用,易造成測試線隱性斷路,或芯線和屏蔽短路,或插頭接觸不良,用戶應經常維護測試線;
測試標準電容試品時,應使用全屏蔽插頭連接,以消除附加雜散電容影響,否則不能反映出儀器精度;
自激法測量CVT時,非的高壓線應吊起懸空,否則對地附加雜散電容和介損會引起測量誤差。
6.7工作模式選(xuan)擇
接好線后請選擇正確的測量工作模式(正、反和CVT),不可選錯。特別是干擾環境下應選用變頻抗干擾模式。
6.8試驗方法影響
由于介損測量受試驗方法影響較大,應區分是試驗方法誤差還是儀器誤差。出現問題時可先檢查接線,然后檢查是否為儀器故障。
6.9儀器(qi)故障(zhang)
用萬用表測量下測試線是否斷路,或芯線和屏蔽是否短路;輸入電源220V過高或過低;接地是否良好。
用正、反接線測下標準電容器或已知容量和介損的電容試品,如果結果正確,即可判斷儀器沒有問題;
拔下所有測試導線,進行空試升壓,若不能正常工作,儀器可能有故障。
啟動CVT測量后測量低壓輸出,應出現2~5V電壓,否則儀器有故障。
 
7. 儀器檢定(ding)
7.1用標(biao)準損耗(hao)器檢定
用帶插頭的屏蔽電纜連接標準損耗器。如果不能保證標準損耗器的精度,應使用比對法檢定,建議用2801電橋或其它精密電橋作比對標準。
儀器應選用“內標準”和“RC串聯試品”,可選擇工頻 50Hz或定頻50Hz頻率模式。
7.2用QSJ3檢定
使用帶插頭的(de)屏蔽電纜連接QSJ3,選擇“正接/ 外Cn / 外Un式測量,電流比(bi)為CxCn,Cn可置(zhi)入適(shi)當值(zhi)。
7.3抗干擾能力(li)
設置個回路向儀器注入定量的干擾電流。
注意:
1)應考慮到(dao)該回(hui)路可能成為(wei)試品的部分。
2)儀器(qi)啟(qi)動(dong)后會使220V供電電路帶有測量(liang)頻率分量(liang),如果該(gai)頻率分量(liang)又通過干擾電流進入儀器(qi),則無法檢驗(yan)儀器(qi)的抗干擾能力(li)。
3)不(bu)建議用臨近高壓導體施(shi)加干(gan)擾,因為這樣很容易產生近距離放(fang)電(dian),這種放(fang)電(dian)電(dian)阻(zu)是非線(xian)性的,容易產生同頻干(gan)擾。
8. 儀器工作原(yuan)理簡(jian)介
8.1儀器結(jie)構(gou)
 
 
 
 
 
儀器結構框圖
測量電路:傅立葉變換、復數運算等全部計算和量程切換、變頻電源控制等。
控制面板:打印機、鍵盤、顯示和通訊中轉。
變頻電源:采用SPWM開關電路產生大功率正弦波穩壓輸出。
升壓變壓器:將變頻電源輸出升壓到測量電壓,zui大無功輸出2kVA / 1分鐘。
標準電容器:內Cn,測量基準。
Cn電(dian)流檢測(ce):用于檢測(ce)內/外標準電(dian)容器電(dian)流。
Cx正接(jie)線電流檢(jian)測(ce):只用(yong)于正接(jie)線測(ce)量。
Cx反(fan)接線(xian)電流檢(jian)測(ce):只用于反(fan)接線(xian)測(ce)量。
反接線數字隔離通訊:用高速數字隔離通訊電路,將反接線電流信號送到低壓側。
8.2工作原理(li)
啟動測量后高壓設定值送到變頻電源,變頻電源用PID算法將輸出緩速調整到設定值,測量電路將實測高壓送到變頻電源,微調低壓,實現準確高壓輸出。根據正/反接線和內/外標準電容的設置,測量電路根據試驗電流自動選擇輸入并切換量程,測量電路采用傅立葉變換濾掉干擾,分離出信號基波,對標準電流和試品電流進行矢量運算,幅值計算電容量,角差計算tgδ。反復進行多次測量,經過排序選擇個中間結果。測量結束,測量電路發出降壓指令變頻電源緩速降壓到0。
CVT測量:CVT隔離開關斷開,低壓隔離開關接通輸出低壓。測量C2時,CVT倒線開關接通,C2接入試品通道,用C1作標準電容測量C2
9. 變(bian)頻測(ce)量討論
9.1變頻測量
干擾十分嚴重時,變頻測量能得到準確可靠的結果。例如用55Hz測量時,測量系統只允許55Hz信號通過,50Hz干擾信號被有效抑制,原因在于測量系統很容易區別不同頻率,由下述簡單計算可以說明選頻測量的效果:
兩個頻率相差1倍的正弦波疊加到起,高頻的是干擾,幅度為低頻的10倍:
Y=1.234sin(x+5.678°)+12.34sin(2x+87.65°)
在x=0/90/180/270°得到4個測量值
Y0=12.4517,Y1= -11.1017,Y2=12.2075,Y3= -13.5576,
計算A=Y1 - Y3=2.4559,B=Y0 - Y2=0.2442,則:
φ=tg-1(B/A)=5.678° V=   A2+B2 / 2=1.234
這剛好是低頻部分的相位和幅度,干擾被抑制。實際波形的測量點多達數萬,計算量很大,結果反映了波形的整體特征。
9.2頻率和介損的關系
介損有RC串聯和并聯兩種理想模型:串聯模型tgδ=2πfRC,并聯模型tgδ=1/(2πfRC),tgδ分別隨頻率f成正比和反比。如圖所示,f對*正比和*反比兩種模型影響較大。但實際電容器是多種模型交織的混合模型,此時f的影響就小。
 
        tgδ  &nbsp;             串聯模型       &nbsp;    tgδ
 &nbsp;                        &nbsp; 介損恒定
 

 
  &nbsp;          &nbsp;              實際(ji)試品
 
    &nbsp;&nbsp;                      并聯模型
                            f                                   f
        低頻介損曲線(<1kHz) ;            高頻介損曲線或低頻電路諧振
9.3自動變頻與50Hz等效
儀器采用自動變頻在干擾頻率50Hz兩側(ce)(45Hz和55Hz)各測(ce)個點(dian),然后(hou)推算50Hz頻率(lv)下(xia)數據。除(chu)多個元件電路的(de)(de)(de)(de)低頻諧振外,單個試品中的(de)(de)(de)(de)介(jie)(jie)質不可能(neng)在低頻引(yin)起(qi)能(neng)量(liang)吸收(shou)峰,工頻附近(jin)介(jie)(jie)損(sun)總是(shi)隨頻率(lv)單調(diao)變化的(de)(de)(de)(de)。因此這種測(ce)量(liang)方法不會(hui)帶來明顯誤(wu)差。實(shi)際上,平均前的(de)(de)(de)(de)兩個介(jie)(jie)損(sun)值(zhi)已(yi)(yi)十分接近(jin),即(ji)使不平均也*有參考價值(zhi)。目前,變頻介(jie)(jie)損(sun)儀已(yi)(yi)成為介(jie)(jie)損(sun)測(ce)量(liang)的(de)(de)(de)(de)常規(gui)儀器,其優異的(de)(de)(de)(de)抗干擾能(neng)力和準(zhun)確度(du)已(yi)(yi)經得(de)到(dao)認可。
 
 
 
 
 
 

 

 

 

 

 

 

 


 

 

 

 

 


 

 

 

 

 

 

 

 

 


 